
AHM5
MAGNETIC ANALOG ABSOLUTE SINGLE TURN ENCODERS, AHM5 RANGE
BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél : +33 (0)3 88 20 80 80
Fax : +33 (0)3 88 20 87 87
Web :
www.beisensors.com
ELECTRICAL DATA
Power supply 5V or 10–30Vdc or 15-30Vdc Introduction < 1 s
Comsumption without load < 40mA (at 24Vdc) < 10 ms (5L2 & 3L1 electronic)
Resolution 12 bits
Response time
< 1ms (other electronics)
Accuracy ± 0.3 % >10kOhms (Voltage output)
Repeatability ± 0.1 %
Advised load
500Ohms (current output)
ANALOG OUTPUT
CONNECTION
0V +Vcc Analog output Ground
L3
3 wire cable
PVC
8230/022
White
WH
Brown
BN
Green
GN
General shielding
L4
M12 connector
4 pinouts
1 2 3 Connector body
* Nota : pinout number 4 is not connected - If extension cable is used: please refer to its wiring arrangement / wire colors
ORDERING REFERENCE (Contact the factory for special versions, ex : stainless steel version, connections…)
Shaft
Supply
Output stage
Direction Resolution Connection
Connection
orientation
L3 :
3 wires cable
PVC
A020 :
Axial
Cable 2m
R020 :
Radial
Cable 2m
AHM5
06 :
Shaft 6mm
10 :
Shaft 10mm
3L1 : 15 to 30Vdc
0..10V output
5L2 : 10 to 30Vdc
0.5..4.5V output
3L3 : 15 to 30Vdc
4..20mA output
2LR : 5V +/- 5%
Ratio 10…90% voltage supply
1 : CW
Clockwise
2 : CCW
Counter-
clockwise
00360 :
Analog output
calibrated on
360°
Other : Consult
us
L4 :
M12
Connector
4 pinouts
A : Axial
R : Radial
Ex: AHM5 _ 10 // 3 L1 1 // 00360 //
L3 R020
Made in France
Changes possible without further notice 100909
Kommentare zu diesen Handbüchern